Foster RBC20-60 User Manual Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
Electrical Connections.
Inputs.
L - Mains ‘Live’ supply (115V 230V, 50Hz / 60Hz). 4 terminals.
N - Mains ‘Neutral’ supply – 16 terminals.
E - Protective Earth – 16 terminals.
DOOR - Door Switching connection (not voltage carrying).
DOOR2 - Safety door switch connection (not voltage carrying).
HP - High Pressure switch connection (not voltage carrying).
TA - Air probe connection.
TE - Evaporator probe connection.
FP1 - Food/ product temperature connection.
FP2 - Additional second food / product temperature probe connection.
FP3 - Additional third food / product temperature probe connection.
Outputs.
C1 - Condensing system switched relay (30A/ 8A) – normally open (NO) output – 3 terminals.
F1 - Evaporator fan 1 switch relay (8A/ 4A) – normally open (NO) output – 3 terminals.
F2 - Evaporator fan 2 switch relay (8A/ 4A) – normally open (NO) output – 3 terminals.
D1 - Defrost system switched relay (8A/ 4A) – normally open (NO) output – 3 terminals.
S1 - UV light system switched relay (8A/ 4A) – normally open (NO) output 2 terminals.
A1 - Alarm relay (8A/ 4A) normally closed (NC) – 1 terminal, normally open (NO) 2 terminals.
P1 - Capacity relay (8A/ 4A) normally closed (NC) – 1 terminal, normally open (NO) 2 terminals.
Display Power - Man Machine socket 2 – way connection.
Display Data - Man Machine RJ54 Type 4 – way connection.
Logger - 4 – way RS 485 connections.
Service Information
Refer to the operating instructions on page 4 for operating instructions.
When mains electrical power is first applied to the controller it will carry out a self test function, for approximately 3
seconds, to ensure that there are good connections between the component parts. During this period the display will
show.
The information displayed in the centre of the screen refers to which of the profiles the controller is set for.
The software version relates to the software release. The number relates to the major operating changes or model
variants. The letter relates to the minor operating changes that may have been made from the original, such as parameter
settings.
On completion of the self test the controller will revert to the last chill program that was run (Pre-chill, Soft Chill, Hard Chill,
Hard Chill Max, Shock Freeze, Professional 1, Professional 2, or Professional 3). The availability of these is dependent on
how the controller has been configured. The example below shows the controller in Hard Chill.
Press and hold the dial for 5 seconds.
Firstly the display will display the information page, below left, continue pressing until the ‘SERVICE’ screen is displayed,
below right. For changes to language see page 5.
7
Page view 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 31 32

Comments to this Manuals

No comments